DCAHT systems already in service for aircraft production and maintenance facilities. |
|
|||||
| |
||||||
DUAL
CHAMBER ALUMINUM HEAT TREATING SYSTEMS
Designed Specifically For Aerospace
Pyrometry
DCAHT SERIES SYSTEMS - NOW SOLD TO MOST MAJOR AIRCRAFT MANUFACTURERS
| General Description:
The DELTA H SYSTEMS Series DCAHT furnace / oven systems features dual chambers and is designed for specifically for aerospace pyrometry - performing a wide variety of aluminum heat treating applications including: solution heat treating, annealing, and aging (precipitation hardening). This system is ideal for aerospace or industrial aluminum heat treating job shops, tool rooms, and research and development applications where extreme flexibility is required - as well as aircraft production and manufacturing. A high temperature chamber is used for solution heat treating and annealing and is designed for efficient operation between the temperatures of 400 degrees F and 1100 degrees F. The low temperature chamber is used for aging and is designed for efficient operation between the temperatures of 200 degrees F and 500 degrees F. A stainless steel, roll away, quench tank is featured under the system and used for quickly quenching loads in water. |
| Operation: Loads for solution heat treating are placed in a basket and then into the lower chamber (can also be placed on the elevated hearth). Upon completion of the required time at temperature an alarm sounds to notify the operator that the heating cycle is complete. The door is manually opened and the basket, or parts, are quickly pulled from the chamber and immediately submerged in the quench tank positioned in front of the oven. Loads for annealing are placed in the lower chamber and the required temperature profile is controlled by a programmable setpoint temperature controller. Loads for aging are placed in the upper chamber at the desired setpoint temperature for the desired length of time. |
Benefits: * Soak time will not begin until the chamber has recovered to near setpoint. * A "Deviation Alarm" will sound if the process temperature drifts too far from setpoint. * Simple to use Honeywell or Partlow temperature programmers / controllers and recorders. |
Standard Sizes (Both Chambers): |
| Design and Performance
Specifications: The design standards for the oven system are per National Fire Protection Association publication NFPA-86, Ovens and Furnaces, 2005 Edition. The system is designed to meet the initial and periodic inspection, calibration and certification standards for temperature uniformity, load heating recovery, and temperature control specification requirements as stated per:
|